Chapter 11: Pipe Materials and Design

11.1 Introduction

This chapter provides guidance on the selection and application of pipe materials used in hydraulic design and construction. Material choice influences the performance, longevity, and maintenance needs of culverts and stormwater systems. Proper selection depends on hydraulic, structural requirements, as well as compatibility with environmental site conditions, and sediment transport. 

This chapter outlines the advantages, limitations, and appropriate uses of commonly accepted pipe materials in accordance with ODOT standards. 

Sections marked with this icon indicate a Required Design Policy. These policies are mandatory and must be followed in all designs. The icon serves as a visual reminder to highlight design requirements. 

11.2 Deviations from Design Standards 

Design deviations from the standards and requirements of this chapter require approval by the State Hydraulic Engineer. The deviation must provide justification and supporting documentation that the proposed alternative is designed in accordance with acceptable engineering practices. Deviations are to be designed in accordance with accepted engineering practice and applicable AASHTO, ASTM, or AWWA standards, as appropriate. The following is a list of common deviations from standards:

  • Not submitting soil and water samples for laboratory testing of pH and resistivity
  • Not meeting the required design pipe service life requirements
  • Use of pipe materials not allowed in Table 11 - 2 or Table 11 - 4
  • Use of alternative pipe material or configurations not identified in this chapter
  • Noncompliance with allowable minimum or maximum cover limits 

Follow procedures for submitting design deviations outlined in Policy Chapter. Obtain the hydraulics design deviation approvals as early as possible and prior to the design acceptance package (DAP). All deviations must demonstrate equivalent or improved performance relative to the governing hydraulic, structural, and durability requirements defined in this chapter. 

11.3 Pipe Classification 

For consistency in design and construction, ODOT has grouped pipes used in highway projects into four main categories based on their function and application. This classification helps guide design decisions and material selection appropriate for each group’s function. The four categories are: Culvert Pipe, Storm Sewer Pipe, Perforated Drain Pipe, and Sanitary Sewer Pipe. Each category is described in the following sections. 

To support appropriate material selection, pipe materials should conform to applicable AASHTO, ASTM, AWWA, and ODOT standards for material properties and manufacture. These standards cover factors including cell class, material strength, internal diameter, loadings, and wall thickness. 

11.3.1 Culvert Pipe 

A culvert is a closed conduit used to convey water along or under the highway system, or past flow obstructions. Culverts are installed to maintain hydraulic continuity of natural and constructed drainage systems. They function to pass design flows while reducing the risk of roadway overtopping, embankment scour, and impacts to adjacent properties. 

11.3.2 Storm Sewer Pipe 

A storm sewer is a closed drainage system consisting of inlets, manholes, and conduits used to collect and convey stormwater runoff. Storm sewer pipes are designed to transport runoff from roadways, shoulders, and adjacent developed areas to a discharge point, outfall, outlet or stormwater facility. All storm sewer systems require pressure testing in accordance with Standard Specification 00445. Pressure testing identifies leaking seams, joints, or other deficiencies from installation or manufacturing. 

11.3.3 Perforated Drain Pipe 

A perforated pipe is a pipe designed with small holes or slits, known as perforations along the pipe surface. These pipes are used to manage excess water by collecting and conveying the water away from areas such as stormwater facilities, roadbeds or retaining walls. Perforated drain pipes are typically small in diameter (6 to 8 inches), although larger diameters may be specified depending on design requirements. 

11.3.4 Sanitary Sewer Pipe 

Sanitary sewer pipes are used to convey domestic or industrial wastewater to treatment facilities. While not typically owned or maintained by the highway agency, these pipes may be present within or adjacent to the highway right-of-way. 

11.4 Pipe Material Selection Process 

Selecting pipe materials for culverts and storm sewers requires consideration of the required design service life to ensure long-term performance. The required design service life is defined in Section 11.5, and is determined before evaluating candidate pipe materials. 

Table 11 - 1 provides an outline for evaluating and selecting pipe materials. The process guides the designer through service life requirements by pipe classification, durability, hydraulic performance, and structural requirements. This process supports consistent evaluation of material alternatives and ensures long-term performance requirements are met during selection.

Table 11 - 1 Pipe Materials Selection Process
Steps
Design Considerations
Chapter References
1Determine design service life for the application
Select preliminary approved materials by application
11.5 Design Service Life
2Review pipe material options, including coatings, connections, and corrugations 11.6 Pipe Materials
3Evaluate hydraulic performance and Manning's n 11.6.4 Manning's n
4Evaluate site conditions for: corrosion, chlorides and sulfates, and abrasion 11.7 Material Performance
5
Evaluate pipe for needed corrosion or abrasion mitigation or protection 11.8  Chemical and Physical Site Conditions
6Select appropriate pipe material for wildfire-prone areas 11.9 Material Selection in Fire Prone Areas
7Verify fill height for minimum and maximum cover limits.
Confirm bedding and pipe zone, meet design requirements
11.11 Installation Requirements
8Review shallow cover and protective measures if needed. 11.12 Shallow Cover Conditions
9Compare alternative material designs, including cost and select final pipe solutionsReevaluate steps 2- 8 above if needed.
10List the selected pipe material and any cost-effective alternate materials identified in Step 9 on the Pipe Data Sheet.

11.5 Design Service Life

Minimum design service life criteria are established to guide material selection based on application type, potential safety impacts, and long-term replacement costs. 

Design service life: The expected operational lifespan of a culvert, storm sewer, or sanitary sewer pipe before material deterioration significantly affects hydraulic or structural performance. 

Table 11 - 2 lists the minimum design service lives and approved pipe materials by type of hydraulic application. Designers are responsible for evaluating site-specific conditions and selecting materials that meet or exceed the required design service life to ensure long-term performance and public safety. When multiple design lives are specified for an installation, the longer design life governs.

Pipe Service Life and Materials
■         Recommended -  meets expected performance, durability, and maintenance requirements.
●         Limited - Acceptable with design or site considerations; may need additional evaluation or protection.
X          Not Allowed -  Prohibited due to performance, durability, or policy limitations

Table 11-2 Required Design Service Life and Approved Pipe Materials
Application Type

Design Service Life (years)Galvanized SteelAluminumized SteelPolymer Coated SteelAluminumDuctile Iron PipeConcrete – Reinforced (III – IV)Concrete – Non-ReinforcedHDPE Solid Wall (Fussed)
Corrugated HDPEPVC+Polypropylene Pipe+HDPE - Steel Reinforced
Culverts                         
All Cross Culverts 75 ■ ■ ■ ■
■ ■ X ● X X X ●
Approach Roads
25 ■ ■
■ ■ ■ ■ ● ■ ■ ■ X ■
Outside of shoulders / Roadway Fill 50 ■ ■ ■ ■ ■ ■ ■ ■
■ ■ X ■
Storm Sewer
Within Traveled Way / Shoulders 75 ■ ■ ■ ■ ■ ■ X ● X ? ? ●
Outside Traveled Way / Shoulders 50 ■ ■ ■ ■ ■ ■ ● ● ? ? ? ●
Perforated Drains 
All Cross Drains 75 ■ ■ ? ■ X ■ ? X X ■ ■ X
Outside Traveled Way / Shoulders
25 ■ ■ ? ■ X ■ ? X ? ■ ■ X
Sanitary Sewer
Check with local municipality or jurisdiction for requirements if the project is under their control.

+ See Table 11 - 4 Approved Thermoplastic Pipe Applications for more detail.

11.6 Pipe Materials

This section provides descriptions and performance characteristics of common pipe materials used in hydraulic infrastructure, including culverts, storm sewers, and sanitary sewer pipes. Material selection is important to ensure structural integrity, hydraulic efficiency, and long-term durability under varying environmental conditions.

See Section 11.8.1 for guidance on evaluating corrosive environments and selecting appropriate protective measures for all pipe materials.

11.6.1 Concrete Pipe

Concrete pipe is used for all four pipe classifications. Long-term performance makes concrete pipe a standard material in transportation infrastructure. Types include non-reinforced (NRCP) and reinforced (RCP), and reinforced concrete box culverts (RCBC) with selection based on loading conditions and design requirements. Concrete pipe strength is categorized from Class I through Class V, with structural capacity increasing with each class. Class 1 NRCP and Class I and II RCP lack structural strength for most applications and are rarely used.

RCP combines concrete to resist compressive forces with embedded steel reinforcement to handle tensile forces. Concrete pipe is classified as a rigid pipe, relying primarily on its structural strength to support load. RCBCs are reinforced structures configured with a rectangular cross-section, making them suitable for shallow cover conditions, and vertical low-profile roadway embankments. RCBCs are also classified as rigid structures, relying primarily on structural strength to support applied loads.

Caution is advised when using concrete pipe in sanitary sewers, as hydrogen sulfide gas buildup can cause severe corrosion and deterioration. Protective linings or coatings are recommended in areas prone to high concentrations of sulfide gas. Consult the local municipality to determine if concrete pipe is an acceptable alternative at a given location.

11.6.1.1 Concrete Pipe Connections

Several joint systems are used to connect concrete pipe and meet performance requirements. Precast concrete pipe joints are manufactured in two types: tongue and groove, and bell and spigot. Figure 11 - 1 and Figure 11 - 2 show example connection types.

Joints with a groove or bell utilize a rubber gasket, which fits against the shoulder or in the groove of the joint. Rubber gasketed pipe joints are frequently used where infiltration, exfiltration, or internal pressure is a factor in the design and are required for storm sewer and culvert applications. This joint provides great shear strength, excellent watertightness and flexibility.

For tongue-and-groove joints, a mastic field-applied sealant may be used to supplement joint sealing. The mastic improves bearing contact between joint faces and is not intended to replace gasketed joints where watertight performance is required.

Ch11-Fig-11-1.png 
Figure 11-1 Concrete Modified Tongue and Groove Connection

Ch11-Fig-11-2.png 
Figure 11-2 Concrete Bell and Spigot Joints

Pipe sections near culvert ends can separate if there is a loss of support from the underlying fill. Install tie-bars at the first two and last two pipe joints, as shown in Oregon Standard Drawing RD318.

Precautions must be taken when concrete pipe is placed on grades greater than 10 percent or when significant settlement is expected, as joint separation may occur. Allowable methods and materials for joining concrete pipes are described in the Oregon Standard Specifications for Construction.

11.6.2 Metal Pipe

Metal pipes systems are fabricated from a variety of base metals including aluminum, steel, and ductile iron. Each material is selected for strength, durability, corrosion resistance. Protective coatings are applied to metal pipe to increase durability in corrosive environments. Metal pipe is available in a range of sizes and shapes. Common configurations include corrugated steel pipe (CSP), spiral-welded steel pipe, and ductile iron pipe.

Metal culverts are classified as flexible pipe, and resist loads primarily through soil–structure interaction with the surrounding bedding and backfill. Common use of metal pipes are culverts and storm sewers due to their strength, durability, and ease of fabrication.

Aluminum

Aluminum pipe is fabricated from corrosion-resistant aluminum alloys, providing excellent resistance to weathering and corrosion. When aluminum is exposed to water and air, an oxide layer forms that protects the underlying metal. Aluminum pipe performs best in soils with a pH between 4.0 - 9.0 and resistivity above 1,000 ohm-cm. Aluminum pipes are available as corrugated or spiral-ribbed.

Aluminum is the preferred metal pipe alternative for marine and coastal environments due to the strong resistance to chloride-induced corrosion compared to steel-based materials. Performance is dependent on site-specific conditions, including exposure severity and the potential for galvanic corrosion at connections.

Steel

Steel pipe provides high strength and stiffness, making this material suitable for a wide range of culvert and storm sewer applications. Bare steel is susceptible to corrosion when exposed to soil, water, and especially marine environments. To improve corrosion resistance protective coatings are applied to extend the service life. See Section 11.6.2.2 for additional information on steel pipe coatings.

Ductile Iron

Ductile iron pipe (DIP) is a strong, durable pipe used primarily for high-pressure water distribution and sanitary sewer systems. In transportation applications, DIP is selected as an alternative where other prospective pipe materials do not satisfy site-specific cover constraints identified in manufacturer fill height tables. Thickness classed for DIP range from 50 to 56, specifying the minimum wall thickness to withstand external loads. Pressure classes range from 150 to 350 psi, defining the pipe’s capacity to resist internal pressure for water and wastewater applications. See Section 11.12 11.11, Shallow Cover, for additional guidance.

11.6.2.2 Steel Pipe Coatings

Protective coatings are applied to steel pipe to improve corrosion resistance and extend service life in aggressive environments. Coatings act as a barrier between the metal and the soil or water, reducing oxidation and chemical attack. Selection of coating type should consider soil and water pH, resistivity, abrasion, and required design service life. For guidance on the evaluation and mitigation of corrosion and abrasion, see Sections 11.7 and 11.8.

Aluminized Steel

Aluminized steel pipe is steel coated with an aluminum-silicon alloy. The aluminum layer forms a barrier against moisture and oxygen, reducing oxidation of the steel substrate. Aluminized steel pipe provides greater durability than galvanized steel and performs best in alkaline soils with a pH between 5.0 - 9.0 and resistivity above 1,500 ohm-cm. Low-resistivity, acidic, or chloride-rich soils may reduce service life.

Galvanized Steel

Galvanized steel pipe is produced by hot-dip coating steel with a layer of zinc. The zinc layer offers both barrier and sacrificial protection, delaying corrosion of the underlying steel. Galvanized pipe performs best in neutral to slightly basic soils (pH 6.0–10.0) with resistivity above 1,500 ohm-cm. Galvanized pipe is less durable than aluminized or polymer-coated steel and should not be used in highly acidic or chloride-rich soils.

Polymer Coated Steel

Polymer-coated steel pipe is galvanized steel with a bonded polyethylene or polyolefin film applied to both interior and exterior surfaces. This coating provides a corrosion and abrasion-resistant barrier, making the pipe suitable for soils with pH between 4.0 and 10.0 and low resistivity. Polymer coated steel is used in highly corrosive environments where extended service life is required. Polymeric coatings must meet the minimum thickness requirements in ASTM A742 or AASHTO M 246.

Use of polymer-coated steel pipe is limited to diameters of 36 inches and under due to manufacturing and coating application constraints. Use of larger diameters requires approval from the State Hydraulics Section.

11.6.2.3 Metal Corrugations and Wall Thickness

Corrugated metal pipe (CMP) is produced with three types of corrugation geometry: annular, helical, and spiral rib. Corrugation size and geometry influence the pipe’s structural capacity, durability, and hydraulic performance. The corrugations are defined by their pitch (the distance between corrugation crests) and depth (the distance from crest to trough) as shown in Figure 11 - 3. Larger corrugation sizes are used as the pipe diameter increases.

Ch11-Fig-11-3.png  
Figure 11-3 Corrugation Diagram


Common metal corrugation size includes (pitch x depth):

  • 2 2/3 inches x 1/2 inches
  • 3 inches x 1 inch
  • 5 inches x 1 inch
  • 6 inches x 2 inches

Annular Corrugations

Annular corrugations are oriented perpendicular to the pipe’s longitudinal axis, forming a series of evenly spaced rings around the pipe, see Figure 11 - 4. This configuration provides high radial strength and resistance to deformation. Annular corrugations are common on older corrugated metal pipe. They are used on the ends of pipes with helical corrugations to facilitate band coupling.

Ch11-Fig-11-4.png  
Figure 11-4 Annular Corrugations

Helical

Helical corrugations form a continuous spiral along the length of the pipe and are the most commonly manufactured corrugation type, see Figure 11 - 5. The spiral seam may be fabricated with a gasketed lock-seam for watertightness or a non-gasketed lock-seam. This design produces a continuous interior wall without circumferential ridges, improving hydraulic efficiency in certain diameters.

Ch11-Fig-11-5.png  
Figurte 11-5 Helical Corrugations

Spiral Rib

Spiral rib pipe combines a helical seam with rectangular external ribs that wrap around the pipe similar to helical pipe, see Figure 11 - 6. The interior wall between ribs is nearly smooth, providing a low Manning’s n value comparable to reinforced concrete or smooth plastic pipes.

Ch11-Fig-11-6.png
Figure 11-6 Spiral Rib with Locking Seam (National Corrugated Steel Pipe Association)

Wall Thickness

Wall thickness is specified to the nearest 0.001 inch. Standard wall thicknesses and corresponding gage values are listed in Table 11 - 3. Gage values are commonly used in the pipe industry and specifications.

Table 11-3.1 Galvanized Steel Wall Thickness and Gage Values
Wall ThicknessGage
0.064 in16
0.079 in14
0.109 in
12
0.138 in
10
0.168 in8

Table 11-3.2 Aluminum Wall Thickness and Gage Values
Wall ThicknessGage
0.060 in16
0.075 in14
0.105 in12
0.135 in10
0.164 in8

Note: Applies to uncoated or metallic-coated pipes. See Fill Height Tables in the Oregon Standard Drawings for available thicknesses.